The HY4300 series Multi-channel Temperature Tester includes HY4308/HY4316, which respectively corresponding to 8, 16 channels. Instrument 4.3 inches LCD color screen display, page beautiful, can be simultaneously on the multi-channel data acquisition, on the super lower super alarm and communication transmission, compatible with a variety of temperature sensors, fast response speed, data stability.
4.3-inch LCD true color LCD display
Equipped with extensive adaptability, supporting KN/E/T/R/S/B type thermocouples
Test range: -200 ℃ · 1800 ℃
Temperature test main parameter display with 6 digits, resolution up to 0.01 ℃
Two scanning speeds: fast (depending on different models), slow
Automatic detection of broken couples
Intuitive numerical reading
Cold end compensation
Support USB storage
File management is available, and the current instrument settings will not be lost when shutting down
The instrument comes standard with a 2-meter K-type thermocouple test line, which can measure temperatures ranging from -20 ℃ to 200 ℃
Specially designed temperature upper and lower limit over limit alarm and over limit reading change warning, which can set the upper and lower limits for each temperature data channel
Suitable for standard 2U cabinets
Suitable for household appliances, motors, electric heating appliances, temperature controllers, transformers, ovens, thermal protectors, power supplies, lighting
Manufacturers and quality inspection departments in industries such as power and LED conduct multi-point temperature testing,

| model | HY430eight | HY43sixteen | |
| number of channels | eight | sixteen | |
| Measurement display | Intuitive numerical display | ||
| interface | USB HOST、RS232C | ||
| graduation mark | Thermocouples J, K, T, E, S, N, B, R | ||
| test scope | -200 ℃ -1800 ℃ (varies depending on different thermocouple models) | ||
| resolution | 0.01℃ | ||
| number of channels | 8-sixteen channels (equipped according to different product models) | ||
| Power supply voltage frequency | AC100-240V50/60Hz | ||
| Indicator temperature and humidity | Temperature: 15℃- 35℃, humidity: less than 80%RH | ||
| Sensor Model | Test temperature range (℃) | Measurement accuracy (℃) | Instructions |
| T-type thermocouple | -150 ℃ to 0 ℃ | ±1.0 | 1. This is the instrument accuracy and does not include standard contact compensation accuracy. 2. The standard contact compensation adds ± 0.5 ℃ to the measurement accuracy of the thermocouple. 3. The measurement accuracy of thermocouple sensors is mainly based on the standards of the sensor manufacturer. 4. The standard K-type test line for the instrument has a temperature resistance range of -20 to 200 ℃; The measurement accuracy is ± 1.2 at -20 to 0 ℃ and ± 0.8 ℃ at 0 to 200 ℃. 5. The isolation voltage between instrument channels is 350V DC and 230V AC. |
| 0 ℃ to 400 ℃ | ±0.8 | ||
| Type K thermocouple | -100 ℃ to 0 ℃ | ±1.2 | |
| 0 ℃ to 1350 ℃ | ±0.8 | ||
| J-type thermocouple | -100 ℃ to 0 ℃ | ±1.0 | |
| 0 ℃ to 1200 ℃ | ±0.7 | ||
| N-type thermocouple | -100 ℃ to 0 ℃ | ±1.5 | |
| 0 ℃ to 1300 ℃ | ±0.9 | ||
| E-type thermocouple | -100 ℃ to 0 ℃ | ±0.9 | |
| 0 ℃ to 850 ℃ | ±0.7 | ||
| S-type thermocouple | 0 ℃ to 100 ℃ | ±4.5 | |
| 100 ℃ to 300 ℃ | ±3.0 | ||
| 300 ℃ to 1750 ℃ | ±2.2 | ||
| R-type thermocouple | 0 ℃ to 100 ℃ | ±4.5 | |
| 100 ℃ to 300 ℃ | ±3.0 | ||
| 300 ℃ to 1750 ℃ | ±2.2 | ||
| Type B thermocouple | 600 ℃ to 800 ℃ | ±5.5 | |
| 800 ℃ to 1000 ℃ | ±3.8 | ||
| 1000 ℃ to 1800 ℃ | ±2.5 | ||
| Ordering Information | |||
| Standard Accessories | HY401: K-type thermocouple x 8 pieces (2 meters/piece) (only HY4308) HY401: K-type thermocouple x 16 pieces (2 meters/piece) (only HY4316) 8GB USB flash drive Standard data acquisition software HY106: RS232 communication cable | ||